DC AC Current detecting Current Sensors Applied or used in Railway Metro and Transit
DC AC Current detecting Current Sensors Applied or used in Railway Metro and Transit
DC AC Current detecting Current Sensors Applied or used in Railway Metro and Transit
CHB_U15D
Model :
CHB_U15D
Nominal Current (RMS) :
100/200/300/400A
Vout/Iout @Ipn :
100/150/133.3mA
Measuring Range :
0-900A
Supply Voltage DC :
±12~18V
Accuracy (%) @Ipn +25°C :
0.5
Mounting (mm) :
Ø20mm

Electrical dataTa=25℃±5℃

Parmeter Ref

CHB100U15D100

CHB200U15D100

CHB300U15D150

CHB400U15D133

Rated input Ipn(A)

100

200

300

400

Measuring range Ip(A)

300 (±18V, 22)

600 (±18V, 20)

750 (±18V, 15)

900 (±18V, 3.0)

Turns ratio Np/NS (T)

1:1000

1:2000

1:2000

1:3000

Rated output  Isn(mA)

100±0.5%

100±0.5%

150±0.5%

133.3±0.5%

Coil resister   (Ω)

30

35

30

53

Supply voltage  VC(V)

±12~±18

Power consumption  IC(mA)

20+IpX(Np/Ns)

Zero current       (mA)

@Ip=0                           ≤±0.2

Offset drift (mA)

@ -40℃~85 ≤±0.5

Response time tra(µs)

@100A/μ S,10%- 90% 1.0

Linearity error  εr(%FS)

@Ip=0-±Ipn 0.1

Galvanic isolation (KV)

@ 50HZ,AC,1min 6

Di/dt accurately followedA/µs

100

Bandwidth  BW(KHZ)

@ -3dB DC…100


General data

 Parameter

Value

Operating temperature  TA(°C)

-40 ~ +85

Storage temperature  TS(°C )

-40~ +125

Mass M(g )

125

Plastic material

PBT G30/G15, UL94- V0;

Standards

IEC60950-1:2001

EN50178:1998

SJ20790-2000


Dimensions(mm):

Remarks

1. All dimensions are in mm.

2. General tolerance ±1mm.

Need Help
You have a Measurement problem, we have the Sensing solution.
CONTACTS

Tel:+86(0)25-8556 0520
Tel:+86(0)25-8599 6365
MP:+86-188 5113 2317
anna.lei@cheemi-tech.com
WhatsApp: +86-188 5113 2317
Wechat: 18824256810
3/F, Building 6, Jingang Science and Technology Innovation Park, No.1 Kechuang Road, Qixia District, Nanjing, China.

Copyright © 2015-2024 CHEEMI TECHNOLOGY CO., LIMITED. All Rights Reserved. Current Sensors Sitemap